Console
30 Years in quality & reliable power system solutions

FM Series

VISION FM series are designed for general-purpose applications, such as UPS, telecom, and electrical utilities.
With 10 years design life, the batteries comply to the most popular international standards, such as IEC896-2, BS6290-4, Eurobat Guide.
The battery container and cover are available both in V0 class flame retardant ABS or HBO ABS plastics.
With more than 15 years of production experience, VISION FM series of VRLA batteries are recognized as the most reliable and high quality battery system in the industry

Product Standards
You can expect our batteries meet with the standards JIS, DIN, IEC & BS6290-4. We have obtained ISO9001 & ISO14001 certification. We have obtained UL approval (MH25860) for all types of batteries. We have obtained CE approval for all types of batteries. All these render our batteries to be compatible with requirements of world-level equipments

General Specifications

Type Nominal Voltage
(V)
Capacity
(Ah)
Dimension(mm/Kg[+-5%)]) Dimension(Inch/Pound[(+-5%)]) Terminal
Length width Height Total Height Weight Length Width Height Total Height Weight
3FM180D-X 6 180 306 168 220 225 28.6 12.05 6.61 8.66 8.86 63.1 M8
3FM225-X 6 225 320 176 225 230 30.5 12.60 6.93 8.86 9.06 67.3 M8
3FM225S-AM 6 225 260 180 247 267 31 10.24 7.09 9.72 10.51 68.3 AM
6FM7.2 12 7.2 151 65 94 100 2.5 5.94 2.56 3.70 3.94 5.51 F2
6FM12 12 12 151 98 95 101 3.67 5.94 3.86 3.74 3.98 8.1 F2
6FM17-X 12 17 181 77 167 167 5.5 7.13 3.03 6.57 6.57 12.1 M5
6FM24-X 12 24 166 175 125 125 8.6 6.54 6.89 4.92 4.92 19 M5
6FM33-X 12 33 195 130 155 168 11 7.68 5.12 6.10 6.61 24.3 M6
6FM40-X 12 40 197.5 165.5 170 170 14.7 7.78 6.52 6.69 6.69 32.4 M6
6FM40E-X 12 40 197.5 165.5 170 170 13.8 7.78 6.52 6.69 6.69 30.4 M6
6FM45-X 12 45 197.5 165.5 170 170 14.6 7.78 6.52 6.69 6.69 32.2 M6
6FM55S-X 12 55 224 132 205 210 17.3 8.82 5.20 8.07 8.27 39.7 M6
6FM55X 12 55 239 132 205 210 17.3 9.41 5.20 8.07 8.27 36.84 M6
6FM55SG-X 12 55 229 138 208 213 18.5 9.02 5.43 8.19 8.39 43 M6
6FM60B-X 12 60 258 166 206 211 24 10.16 6.54 8.11 8.31 52.9 M6
6FM60-X 12 60 258 166 206 215 24 10.16 6.54 8.11 8.46 52.9 M6
6FM65-X 12 65 350 167 179 179 23.4 13.78 6.57 7.05 7.05 51.6 M6
6FM75-X 12 75 258 166 206 215 24 10.16 6.54 8.11 8.46 52.9 M6
6FM80-X 12 80 350 167 179 179 24 13.78 6.57 7.05 7.05 52.9 M6
6FM90T-X 12 90 306 169 210 215 30 12.05 6.65 8.27 8.46 66.1 M6
6FM100E-X 12 100 330 171 215 222 29.5 12.99 6.73 8.46 8.74 65.07 M8
6FM100F-X 12 100 330 171 215 222 30 12.99 6.73 8.46 8.74 66.2 M8
6FM100HX 12 100 330 171 215 222 32 12.99 6.73 8.46 8.74 70.5 M8
6FM100-X 12 100 330 171 215 220 32 12.99 6.73 8.46 8.66 70.6 M8
6FM120-X 12 120 410 176 227 227 38 16.14 6.93 8.94 8.94 83.8 M8
6FM120HX 12 120 410 176 227 227 38 16.14 6.93 8.94 8.94 83.8 M8
6FM134-X 12 134 342 172 273 277 42.5 13.46 6.77 10.75 10.91 93.7 M8
6FM150-X 12 150 485 172 240 240 47 19.09 6.77 9.45 9.45 104 M8
6FM150HX 12 150 485 172 240 240 47 19.09 6.77 9.45 9.45 103.6 M8
6FM150E-X 12 150 485 172 240 240 44.8 19.09 6.77 9.45 9.45 98.8 M8
6FM180SHX 12 180 522 238 218 223 62 20.55 9.37 8.58 8.78 136.7 M8
6FM200S-X 12 200 522 238 218 223 65 20.55 9.37 8.58 8.78 143 M8
6FM200SHX 12 200 522 238 218 223 65 20.55 9.37 8.58 8.78 143.3 M8
6FM230-X 12 230 520 269 203 208 72.6 20.47 10.59 7.99 8.19 160.1 M8

General Features

Higher Reliability and Quality

Throughout the whole manufacturing process, PPM and ISO 9001 are carried out to make sure that the product reliability and defect ratio meet with the PPM standard.

Higher Power Density

A special assembly technology is used to enhance power density to a considerable level.

Reliable Construction

The extra strong construction ABS container reduces case bulging and plate warping, ensuring long life and high performance.

Valve regulating
Perfect venting system, which operates under low pressure, is designed to release excess gas and keep the internal pressure within the optimum range of safe and efficient performance.

Excellent Recovery from Deep Discharge

Unique technical processes are used into the grid alloy and electrolyte additives, so that the battery can be recharged easily to a normal level even after being over-discharged.

Living Up to Prevailing Standards
The batteries live up to standards JIS, DIN, BS and IEC.

Construction
These reactions can take place only by using :

  • Plates composed of special alloy with several components which provide the plate grids with high mechanical strength and a high level of hydrogen over voltage.
  • An appropriate ratio between positive and negative active materials.
  • Fiberglass separators manufactured from borosilicate, giving them excellent resistance to high temperatures and to sulphuric acid. The high level of porosity of these separators is used to retain the quantity of electrolyte necessary for cell operation, but without any free electrolyte.
  • A pressure relief valve which all

Charge Characteristics
The cells in the VISION FM product range must be charged at a constant voltage at an ambient temperature of 20oC, the batteries should be charged at 2.27-2.30 volts per cell. It is not necessary to limit the current, as this will be governed by the maximum output available from the charger until the voltage limit is reached. The charging voltage of 2.27-2.30 volts should also be used for float charging. To achieve nominal performance characteristics, it is recommended to adjust this value to suit the ambient temperature, as indicated in the following table: Under these conditions a full recharge will be completed in approximately 48 hours.

Fast recharge:
Increasing the charge voltage to 2.40 Volts per cell can reduce recharge time and it is possible, depending on the depth of discharge, to halve the recharge time. Under these conditions, however, the charge must be monitored and must be terminated when the charge current remains reasonably steady for 3 hours
after the voltage limit has been reached. At the beginning of charge the current must be limited to 0.3C10 (A).

Ripple current:
The ripple content of the charging current affects the life of the battery. It is recommended to limit the continuous ripple current to 0.05 C10 (in amperes) as recommended value (never exceed 0.10C10). Transient and other ripple type voltage excursions can be accommodated provided that, with the battery disconnected, the system peak to peak voltage including regulation limits falls within 2.5% of the recommended float voltage of the battery.

Technical Manual

VISION CP series valve regulated lead acid batteries are designed with AGM(Absorbent Glass Mat) technology and for general application purpose, such as UPS, telecom, and electrical utilities.
with 5 years design life, the batteries comply to the most popular international standards, such as IEC896-2, BS6290-4, Eurobat Guide.
The battery container and cover are available both in V0 class flame retardant ABS or HBO ABS plastics.


Home | About Us | Privacy Policy | Terms & Condition
Copyright 2015. www.console.lk. All Rights Reserved

Contact Us

Console Electronics (Pvt) Ltd.
9, Dewale Road,
Pagoda,
Nugegoda,
Sri Lanka.
Tel : +94 11 4650200
Fax : +94 11 4389366